Purchasing over $3,500? Contact us for further discounts. Over 250,000+ Products Available and Growing!
Fisherbrand Handheld Analog Clinical Refractometer #12-561-340

Fisherbrand Handheld Analog Clinical Refractometer #12-561-340

We only sell to businesses, clinics, government facilities, individuals may contact us by email - info@go3a.com

Item#: Fis-12-561-340-EA

$160.01
Item(s) Total: $160.01
Fisherbrand Handheld Analog Clinical Refractometer, 6.772" x 1.535" x 1.535" for Clinical Refractometer, Includes: Calibration Screw Driver, Soft sided case, Applicator, Manual, sold as Each by Fisher Scientific 12-561-340

BACK TO THE PRODUCT TABLE, CLICK HERE
  • PRODUCT DETAILS
  • GOT QUESTIONS
  • RECENTLY VIEWED


  • Product Details
  • Manufacturer # 12-561-340
    Manufacturer Fisher Scientific
    Country of Origin Unknown
    Application Fisherbrand™ Handheld Analog Clinical Refractometer
    Product Type Refractometer
    Type Clinical
    Accuracy 0.002; 0.2 g/dl; 0.0005
    For Use With (Application) Clinical
    Height (Metric) 39mm
    Increments 0.002; 0.2 g/dl; 0.0005
    Lighting Type Ambient
    Refractive Index 1.331 to 1.36nD
    Length (Metric) 204mm
    Weight (Metric) 0.4kg.
    Width (Metric) 39mm
    Sample Volume 1mL
    Scale Type Linear
    Quantity 1
    Calibration Distilled Water
    Scale Range Urine Specific Gravity 1.000 to 1.050; Serum Protein 1 to 12 g/dl; Refractive Index 1.334 to 1.360
    Height (English) 1.535 in.
    Includes Calibration Screw Driver, Soft sided case, Applicator, Manual
    Length (English) 6.772 in.
    Resolution 0.0005
    Temperature Compensation No
    Weight (English) 0.881 lb
    Width (English) 1.535 in.
    Dimensions (L x W x H) 172 x 39 x 39mm

    Features

    • Refractometers have been used for measuring the concentration of solutions for more than a century. Their primary purpose is to measure the degree at which light bends as it passes through a medium, and is used in a wide range of applications and industries as a quality control and diagnostic tool.
    • Fisherbrand Analog Refractometers are designed for simple operation and built with an all-metal construction for durability. Its industrial design is the most commonly used design among refractometer manufactures as it is a cost-effective model to build.
    • Each unit is inspected in the United States by a factory qualified technician under a rigid quality control process to ensure its accuracy, and performance.

    • Key Features:


    • Quickly calibrate the instrument with a turn of a screw, and distilled water
    • Comfortable eyecup blocks out ambient light and allows for crystal clear viewing of readings
    • Automatic temperature compensation prevents the need for constant re-calibration of the instrument. As the ambient temperature changes, the scale will automatically compensate for the difference in the degree of refraction. This ensures an accurate reading every time
    • All metal construction creates durability. NOTE: Model 12-561-340 comes without ATC
    • Footrest allows the instrument to be set on a flat surface without the worry of it rolling off working surfaces
    • Rubber hand grip is comfortable, easy to grasp. Its non-slip pattern grip reduces that chance of accidentally dropping the instrument
    • Double hinged daylight plates create two points of movement to allow for greater flexibility in movement; making it easy to add samples and clean
    • Portable, easy to use design.

    • Clinical Models:


    • Quickly and accurately get an indication of basic health parameters such as dehydration and blood plasma protein levels. Fisherbrand Analog Clinical Refractometers use three-scales to measure Total Serum Protein, Urine Specific Gravity, and Refractive Index. They are ideal for use in quality control, research, and clinical laboratories.
    • Urine Specific Gravity: 1.000ppt to 1.050ppt with granularity to measure down to 0.001ppt at a 0.002ppt degree of accuracy
    • Serum Protein: 1g to 12g with granularity to measure down to 0.2g/100mL at a 0.2g/100mL degree of accuracy
    • Refractive Index: 1.334nD to 1.360nD with granularity to measure down to .0005nD at a 0.0005nD degree of accuracy.
    We are here to help!
    Type your questions into the comment area below.
    For longer messages email us at: info@go3a.com
    • The BEST WAY to contact is by EMAIL - Use our "Contact Us" page, if you need immediate response, write URGENT on the subject line.
    • Emails are monitored 9 am - 4 pm, Mon-Fri, except Holidays, California Time.
    • Can't find the Exact Size? Contact us ( use "contact us" page) and we will get you the info.
    • Need it Yesterday? we have options for 2-3 days, 4-5 days use the check out page shipping options. Take note: the clock begins the day after the order and excludes week-ends and Holidays.
    • Can't Find the Exact Item but you found the Manufacturer? Send us the Info, and we will locate it for you.
    • Need a Quote? Please email us, be accurate with part#, description and quantities.
    • Overseas Customers? Contact us first before making your purchase.